98
MODEL PART TORQUE OUTPUT
NUMBER RANGE
Nm ft.lb
OPTIONAL ACCESSORIES
Cables, see page 103
OUTPUT A B C D E F G
mm in. mm in. mm in. mm in. mm in. mm in. mm in.
Digital Rotary Transducers
Torque or Torque & Angle
The DRT4 (torque) and DRT5 (torque & angle) transducers cover a torque range from 0.15 to 5000 Nm (0.11 to
3685 ft.lb). DRT5 transducers offer an angle resolution down to 0.5°. The built-in memory provides all transducer
calibration data to Sigma or Delta data collector.
Features: Benefits:
Torque range from 0.15 to 5000 Nm...................................... Transducers used in line with screwdrivers – pneumatic tools
(0.11 to 3685 ft.lb). – impulse tools – electric nutrunners and spindles.
Strain gauges transducer ...................................................... The most accurate and reliable type of torque transducer.
– sensitivity 2mV/V.
– accuracy +/-0.35% full scale.
Built-in smart chip memory with:............................................ No need for transducer selection.
Calibration features: The data collector automatically recognises the transducer
type of transducer – sensitivity – nominal load – serial number.
connected.
Maintenance information: Avoids risk of operator error in selecting a wrong type
date of last calibration – maximum torque applied on transducer.
of transducer.
Unique contact system preventing the .................................. Transducers can be used in line with impulse tools, but not
common problem of ‘brush bounce’. with impact tools.
Angle counting system 0.5° resolution .................................. Checks all types of joints, hard and soft.
Same size for torque or torque & angle transducers ................ No problem of accessibility.
Digital connection between data collector ............................ Insensitive to cable length.
and transducer. Reliability of torque values transmitted to the data collector.
Torque value converted to a digital signal Only one type of transducer cable needed.
close to the strain gauges. Easy to recalibrate by modifying the sensitivity coefficient.
No hardware adjustment.
TORQUE TRANSDUCERS DRT4
DRT 4 H 2 615 165 209 0 0.15-2 0.11-1.5 Hex
1
/4"
DRT 4 H 5 615 165 210 0 0.3-5 0.22-3.7 Hex
1
/4"
DRT 4 H 20 615 165 211 0 1.5-20 1.11-14.7 Hex
1
/4"
DRT 4 Sq 20 615 165 212 0 1.5-20 1.11-14.7 Sq
1
/4"
DRT 4 Sq 25 615 165 213 0 1.8-25 1.33-18.4 Sq
3
/8"
DRT 4 Sq 75 615 165 214 0 5.0-75 3.69-55.3 Sq
3
/8"
DRT 4 Sq 180 615 165 215 0 12.0-180 8.85-132 Sq
1
/2"
DRT 4 Sq 500 615 165 216 0 35.0-500 25.8-368 Sq
3
/4"
DRT 4 Sq 1400 615 165 217 0 95.0-1400 70.0-1032 Sq 1"
DRT 4 Sq 3000 615 165 536 0 200-3000 147-2211 Sq 1-
1
/2"
DRT 4 Sq 5000 615 165 540 0 350-5000 258-3685 Sq 1-
1
/2"
TORQUE & ANGLE TRANSDUCERS DRT5
DRT 5 H 2 615 165 218 0 0.15-2 0.11-1.5 Hex
1
/4"
DRT 5 H 5 615 165 219 0 0.3-5 0.22-3.7 Hex
1
/4"
DRT 5 H 20 615 165 220 0 1.5-20 1.11-14.7 Hex
1
/4"
DRT 5 Sq 20 615 165 221 0 1.5-20 1.11-14.7 Sq
1
/4"
DRT 5 Sq 25 615 165 222 0 1.8-25 1.33-18.4 Sq
3
/8"
DRT 5 Sq 75 615 165 223 0 5.0-75 3.69-55.3 Sq
3
/8"
DRT 5 Sq 180 615 165 224 0 12.0-180 8.85-132 Sq
1
/2"
DRT 5 Sq 500 615 165 225 0 35.0-500 25.8-368 Sq
3
/4"
DRT 5 Sq 1400 615 165 226 0 95.0-1400 70.0-1032 Sq 1"
Hex
1
/4" 116.0 4.56 30.0 1.18 68.0 2.68 56.0 2.20 13.0 0.51 39.0 1.53 25.5 1
Sq
1
/4" 71.5 2.81 30.0 1.18 71.5 2.81 56.0 2.20 13.0 0.51 6.0 0.24
Sq
3
/8" 77.0 3.03 30.0 1.18 74.0 2.91 56.0 2.20 15.0 0.59 8.0 0.31
Sq
1
/2" 87.0 3.42 42.0 1.65 82.5 3.25 58.0 2.28 21.0 0.83 12.0 0.47
Sq
3
/4" 106.0 4.17 52.0 2.05 93.5 3.68 60.0 2.36 26.0 1.02 21.0 0.83
Sq 1" 125.0 4.92 63.0 2.48 104.0 4.09 64.5 2.54 31.5 1.24 29.0 1.14
Sq 1-
1
/2" 165.0 6.50 106.0 4.17 148.5 5.85 88.0 3.46 53.0 2.09 35.2 1.39
GRE_10111_A_O1C11 17/11/09 10:21 Page 98