96
MAIN FUNCTIONS
SIGMA DELTA DELTA
2001/2D 4000/4D 5000/5D
TORQUE
Connection of strain gauge transducers, ART / AWT type or others (for Sigma2001/Delta4000 & 5000 only)
Connection of digital transducers DRT4, DRT5, DTW and DST
Range changeover: Automatic, depending on the transducer selected
Sensitivity: Automatic selection depending on the transducer selected
Transducer load: Automatic selection depending on the transducer selected
Specific: Torque from 1 to 10 000Nm - up to 20 specific transducers can be defined
Transducers: Force from 1 to 50 000 daN Sensitivity 0.5 to 2.5 Mv/v
Units: Nm - N.cm - kg.cm - kg.m - Ft.lb - In.lb - kg - N - daN - Kn
SETTING
Joint: Selection of the type of joint and application: Hard - Standard - Soft and filter value (2 to 2048 Hertz)
Measuring mode: Standard - Impulse Wrenches
Display reset: Manual - External - Automatic (programmable)
Operating Mode: Acquisition mode - Programmable mode
INTEGRATED STATISTICAL CALCULATIONS
CAM, CP and CPK calculation and measurement of mean range on torque
or angle values in accordance with ISO, NF, Q544000 and CNOMO standards.
Calculation of ideal tolerances
Data screening (date or value interval)
Tolerance interval selection
Population homogeneity test
Normal distribution test
Exporting the results
COMMUNICATION
LEDs: Tightening reports
Torque OK - Min. torque - Max torque
Torque OK - Min. torque - Max. torque - Angle OK - Min angle - Max. angle
Inputs: Reset the reading and saving the result - Reset the reading without saving the result
Outputs: 3 torque reports: OK - Min.- Max.
Analog torque output (0-10V)
Memory: Up to 5000 results including, torque, torque & angle, date & time
Up to 5000 results including, torque, date & time
Up to 1000 results including, torque, date & time
Tightening curves
Printer: connected to SubD25 point parallel port with printing:
either in order of occurrence (print after each reading, automatically) / parameters / statistics / curves
or in increments of N readings starting from a given date.
Tachometer
POWER REQUIREMENTS
Power supply: Removable and rechargeable battery of 6 x 1.2 V (7.2V) NiMH
Battery life: 1000 Discharging / Recharging cycles 14 hours 14 hours 14 hours
Automatic stop when not used during the selected
Battery control: Low battery indication - Power miser - Charge level test
Global data backup during battery
Charger: Multi-voltage 115/230 Volts with multi-standard mains power cord
Technical features
Sigma 2001/2D / Delta 4000/4D / Delta 5000/5D
GRE_10111_A_O1C11 17/11/09 10:21 Page 96